Gross Capacity & Farm Well Discharge Calculator
The pump-sizing question: given how much water the crop needs (net capacity), application inefficiency, downtime, and losses in getting water from the well to each field, how big does the well/pump actually need to be? Handles any number of fields sharing one supply.
1. Farm-Wide Capacity
Cg = Cn / [(ELQ/100%)(1−Dt/100%)]
2. Fields Served by This Supply
Each field's own conveyance (field canal/ditch) efficiency accounts for losses getting water from the main supply to that field.
3. Well / Main Supply Discharge
Leave at 100% if the well/main line feeds the fields directly with no shared supply losses.
About this calculator
System capacity has to account for more than just crop demand: application inefficiency and downtime inflate the net capacity into a gross capacity, and then each field's own conveyance losses (and any shared main-canal losses) inflate that further into what the well actually has to discharge.
Qf, field = Cg × Area / (Ec, field/100%) — Qwell = ΣQf / (Ec, main/100%)