Gross Capacity & Farm Well Discharge Calculator

The pump-sizing question: given how much water the crop needs (net capacity), application inefficiency, downtime, and losses in getting water from the well to each field, how big does the well/pump actually need to be? Handles any number of fields sharing one supply.

1. Farm-Wide Capacity

Cg = Cn / [(ELQ/100%)(1−Dt/100%)]

in/d
%
%
—
Gross system capacity (Cg), gpm/ac

2. Fields Served by This Supply

Each field's own conveyance (field canal/ditch) efficiency accounts for losses getting water from the main supply to that field.

Area
Conveyance efficiency
Discharge needed

3. Well / Main Supply Discharge

%

Leave at 100% if the well/main line feeds the fields directly with no shared supply losses.

About this calculator

System capacity has to account for more than just crop demand: application inefficiency and downtime inflate the net capacity into a gross capacity, and then each field's own conveyance losses (and any shared main-canal losses) inflate that further into what the well actually has to discharge.

Qf, field = Cg × Area / (Ec, field/100%)   —   Qwell = ΣQf / (Ec, main/100%)

Textbook Example 5.8: Cn=0.3 in/d, ELQ=65%, Dt=10% → Cg≈9.7 gpm/ac. Two 80-ac furrow fields, field efficiencies 80% and 90%, main canal at 90% → Qf1≈975 gpm, Qf2≈867 gpm, well discharge ≈2,050 gpm. Click "Load textbook Example 5.8" above to see it worked through.